The Clesse ECGE14 is a calibrated spring-loaded external safety valve with an M18 x 1.5 male connection, designed to protect LPG systems and other pressurised fluids against overpressure situations. The valve is set to an opening pressure of 14 bar, ensuring controlled release of the fluid when the safety limit is exceeded.
Clesse ECGE14 Features
| Ref. | Pressure Opening | Connection | Dimension | Air Flow Capacity |
|---|---|---|---|---|
| ECGE14 | 14 bar | M.M18x1.5 | 90 mm | 55.2 |
Note: Airflow capacity is measured at 120% of set pressure (m³/min) ASME
Equipped with a small hole to evacuate water deposits that can build up in the valve area, to avoid distortion in the pressure.
The valve operates by means of a calibrated spring that keeps the shutter closed during normal system operation. When the internal pressure exceeds 14 bar, the force exerted by the fluid overcomes the resistance of the spring, causing the valve to open and relieve the pressure. Once a safe pressure has been restored, the valve closes automatically without the need for external intervention.
Construction
- Body: Brass
- Seat Pad: Brass + NBR
- Spring: Stainless steel
Valve Set
External spring safety valves must be used in conjunction with check-device accessories and the respective gasket.
| Connections | ||||
| Check Device | Gasket | Valve | Tank Connection | Inlet Connection |
|---|---|---|---|---|
| ECGE10 | – | ECGE14 | 1/2″ M.NPT | F.M18x1.5 |
Application
Safety valve for LPG tanks, designed to protect against overpressure.
For further information or other products, please consult our entire LPG range.
Clesse official website