A filter installed on the meter inlet side is required even when the piping includes a filter on the pump upstream side. F-Series filters must not be used as a system filter, but as limited protection for the meter itself.
Filter screens are available in 20, 40, 80, 100, or 200 mesh.
SPECIFICATIONS:
F7 filter:
Suitable for SM5, SM7, SMA7, M5, M7, and M10 meters.
– 2″ (1½” optional) 350 PSI (25 bar), aluminium. Construction materials for Classes 1, 2, 3, 4, 14, 15, 16, and 30. Supplied with cover, or without cover when the air eliminator is used.
– 2″ (1½” optional) 150 PSI (10.5 bar), in cast iron or stainless steel. Construction materials for Class 7, 8, 27, and 37 applications. Easily adaptable to fit an air eliminator when required.
– 2″ (1½” optional) 350 PSI (25 bar), high-pressure aluminium. Construction materials for Class 10 (LPG applications). Other classes available on special request, including Class 12 (NH3). Supplied with cover, or without cover when the air/vapour eliminator is used. Relief valve supplied as required for Class 10 and 12 service.
F15 filter:
Suitable for SM15, M15, and M25 meters.
– 3″ aluminium 350 PSI (25 bar). Construction materials for Class 1, 2, 3, 4, 10, 14, 15, and 16 applications. Supplied with cover, or without cover when the air eliminator is used.
F30 filter:
Suitable for SM30, M30, M40, and M60 meters.
– 4″ (3″ optional) 150 PSI (10.5 bar) aluminium. Construction materials for Classes 1, 2, 3, 4, 14, 15, and 16. Supplied with cover, or without cover when the air eliminator is used.